| Sign In | Join Free | My brakesband.com |
|
Brand Name : GFUVE
Model Number : TEST-630
Certification : CE
Place of Origin : China
MOQ : 1SET
Payment Terms : T/T, MoneyGram, Western Union
Supply Ability : 100set/month
Packaging Details : Wooden box
Allowable range : AC220V±10%
AC current output : 6×0-30A
AC voltage output : 6×0-130V
DC voltage output : 0-300V
DC current output : DC current output
| Electrical parameters | |
|---|---|
| Allowable range | AC220V±10% or AC110V±10%, 50/60Hz±10% |
| Time measurement | 0.1ms-999999.999s |
| AC current output | |
| Phase current output (effective value) | 6×0-30A or 3 × 0-60A |
| Maximum output power | 520VA/phase |
| Maximum parallel current output (effective value) | 0-180A |
| Long-term allowable working value of phase current (effective value) | >10A |
| Allowable working time of maximum current | >11s |
| Accuracy | <±0.2% |
| AC voltage output | |
| Phase voltage output (effective value) | 6×0-130V |
| Line voltage output (effective value) | 0-260V |
| Maximum output power | 70VA/phase |
| Accuracy | <±0.2% |
| DC voltage output | |
| Output range | 0-300V or 6×0-±130V |
| Maximum output power | 130VA |
| Accuracy | <±0.2% |
| DC current output | |
| Output range | -10-10A or 6×0-±10A |
| Maximum output power | 150VA |
| Accuracy | <±0.2% |
| Binary input | |
| Idle contact | 1-20mA, 24V (DC) |
| Electric potential contact | 0-250V (DC) |
| Binary output | |
| Idle contact | 250V/0.5A (DC) |
| Rated output | |
| Frequency error | <±0.01HzHz |
| Phase error | <±0. 2° |
| Waveform distortion | <±0.3% (fundamental wave) |
| Time error | <40µs |
| Output frequency | 0-1050Hz |
| Superposed harmonic wave | 0-21times |
| Time measurement | |
| Test range | 0.1ms-999999.999s |
| Mechanical parameters | |
| Dimensions (L×W×H) (mm) | 360×195×365 |
| Weight (kg) | 16.6 |
| Environmental conditions | |
| Use range | 0°C to 45°C |
| Storage range | -25°C to 70°C |
|
|
High Precision Protection Relay Testing Equipment / Protective Relay Test Set DC Current Output Images |